high temperature wire custom cable design
   

Hook-Up Wire
(UL) Style Appliance Wires
(UL) and C(UL) AWM

high temperature wire
   
Insulation: Fluorinated Ethylene Propylene (FEP)

Conductors: From 30 thru 1/0. Stranded, solid, tinned or silver plated copper.
Aerospace FEP Insulated wires are suitable for a wide range of applications where temperature and chemical suitability is a concern. Aerospace FEP can operate under temperatures of -80°C to 200°C and is inert to virtually all known chemicals.

  Applications:

Internal wiring for appliances and class 2 circuits. Wiring in back panel areas of electronic equipment such as computers, robotics and other industrial equipment. Some styles may be exposed to oil, gasoline, gasoline vapors and other chemicals.

(UL) Style AWG Size Min. Avg. Wall Min. Wall @ Any Point Temp.
(°C)
Voltage
1226 30-20
19-14
.008"
.013"
.007"
.012"
80
80
-
-
1227 32-20
19-10
.008"
.013"
.007"
.012"
105
105
-
-
1330 30-10
8-2
1-4/0
.020"
.030"
.045"
.018"
.027"
.040"
200
200
200
600V
600V
600V
1331 30-10
8-2
1-4/0
.020"
.030"
.045"
.018"
.027"
.040"
150
150
150
600V
600V
600V
1332 30-10 .013" .012" 200 300V
1333 30-10 .013" .012" 150 300V
1371 30-20
19-16
15-10
9-6
.006"
.008"
.013"
.020"
.005"
.007"
.012"
.018"
105
105
105
105
-
-
-
-
1538 30-20
19-15
14-10
9-6
.006"
.008"
.013"
.020"
.005"
.007"
.012"
.018"
105
105
105
105
125V
125V
125V
125V
1577 30-16 .012" .010" 200 -
1591 30-16 .016" .013" 150 300V
1592 30-16 .016" .013" 200 300V
1723 30-16 .010" .008" 200 -
1766 26-18 .002" .002" 80 30V
1847 26-18 .003" .003" 105 30V
1886 30-10 .010" .009" 150 300V
1887 30-10
8-2
1-4/0
.014"
.020"
.030"
.013"
.018"
.027"
150
150
150
600V
600V
600V
1900 30-10 .010" .009" 200 300V
1901 30-10
8-2
1-4/0
.014"
.020"
.030"
.013"
.018"
.027"
200
200
200
600V
600V
600V
10045 30-14 .008" .008" 150 -
10050 30-10
8-2
1-4/0
.018"
.030"
.045"
.016"
.027"
.040"
150
150
150
600V
600V
600V
10072 30-10
9-6
.009"
.020"
.008"
.018"
200
200
150V
150V
10102 30-10
19-16
15-10
9-6
.006"
.008"
.013"
.020"
.005"
.007"
.012"
.018"
200
200
200
200
-
-
-
-
Temperature Marking Not Required For:
1) All AWM rated less than 90°C.

2) All AWG 20 or smaller single cond. 90°C or higher.

3) All AWM with an NEC designation.

4) On individual cond. of a cable with a printed jacket.

Maximum Operating Temperature Rating:
Tinned or Bare copper,
Less than .015" dia. per strand = 150°C Max.
.015" dia. or larger per strand = 200°C Max.

Printing:
Surface printing is optional

All reels are tagged with the corresponding (UL) label.

     
[Profile] [Catalog] [Custom Cable Worksheet] [Services] [Newsletter]
[Contact Us] [On The Shelf Inventory]