plenum cable custom cable design
   

Plenum Cable
MultiConductors / Stranded / Unshielded
(UL) CL2P or CMP
200°C, 150°C and 75°C

plenum cable
Color Code Chart

 

 

AWG 20 (7x28) Tinned Copper

 
Aero P/N # of Cond. Insulation
Thickness
(inches)
Jacket
Thickness
(inches)
Jacket O.D.
(inches)
Lbs/1000'
1261 2 .006 .010 .120 12
1361 3 .006 .010 .127 17
1461 4 .006 .010 .140 22
1561 5 .006 .010 .155 27
1661 6 .006 .010 .170 32
1761 7 .006 .010 .170 37
1861 8 .006 .010 .220 43
1961 9 .006 .010 .220 47
1061 10 .006 .010 .220 52
1161 12 .006 .010 .227 61
1161-15 15 .006 .010 .255 76
1161-16 16 .006 .010 .255 80
1161-19 19 .006 .012 .289 101
1161-20 20 .006 .012 .289 101
1161-25 25 .006 .012 .324 125
           
           
AWG 18 (7x26) Tinned Copper
Aero P/N # of Cond. Insulation
Thickness
(inches)
Jacket
Thickness
(inches)
Jacket O.D.
(inches)
Lbs/1000'
1251 2 .006 .010 .140 16
1251/19* 2 .006 .010 .138 17
1351 3 .006 .010 .149 23
1451 4 .006 .010 .165 30
1451/19* 4 .006 .010 .162 31
1551 5 .006 .010 .182 36
1651 6 .006 .010 .200 43
1751 7 .006 .010 .200 49
1851 8 .006 .010 .260 57
1951 9 .006 .010 .260 64
1051 10 .006 .010 .260 70
1151 12 .006 .010 .269 83
1151-15 15 .006 .012 .306 104
1151-25 25 .006 .015 .390 173
Specifications

Conductor:
Stranded T.C.

Insulation:
FEP

Color Code:
Chart 1

Jackets Available:
FEP (200°C) or
Fluorocopolymer (150°C) Add "K"
Aeroflex (75°C) Add "PV" to P/N

Industry Approvals:
NEC Article 725-CL2P or
NEC Article 800-CMP
C(UL) (CMP only)

Impedance: (FEP only)
(AWG 20) 83 Ohms Nom.
(AWG 18) 75 Ohms Nom.

Vel. of Propagation: (FEP only)
69% Nom.

Capacitance: (FEP only)
(AWG 20) 19 pF/ft Nom.
(AWG 18) 21 pF/ft Nom.

Temperature Rating:
-80°C to +200°C (FEP/FEP)
-40°C to +150°C (FEP/E-CTFE)
-5°C to +75°C (Halar/Aeroflex)

Put Ups:
1000 Feet (+/- 10%)
(Available in Bulk Reels)

Add to P/N:
*HPV = for Halar/Aeroflex
*R = for Red Jacket CMP/200°C
*KR = for Red Jkt. CMP/150°C

 
[Profile] [Catalog] [Custom Cable Worksheet] [Services] [Newsletter]
[Contact Us] [On The Shelf Inventory]